PRODIK-T 25

Automatically tuned impedance matching network for low power applications

 

Operating frequency: 13.56 MHz
Nominal power: 1.5 kW
Max. power: depends on the load impedance
Max. load current: 25 A
Coolant: forced air
Input connector: 7/16 jack
Output connector: 7/16 jack
Control system: local via CAN-Bus
Interfaces: RS 232 or Profibus
 

 

Dimensioned drawing: 


PRODIK-T 50

Automatically tuned impedance matching network

 

Operating frequency: 13.56 MHz
Nominal power: 5 kW
Max. power: depends on the load impedance
Max. load current: 50 A
Coolant: water
Input connector: 7/16 jack, 7/8'' EIA (optional)
Output connector: 7/8'' EIA
Control system: local via CAN-Bus
Interfaces: RS 232 or Profibus
 

Dimensioned drawing: 

PRODIK-T 50/C

Automatically tuned impedance matching network with cylindric design (for round cathodes)

 

Operating frequency: 13.56 MHz
Nominal power: 5 kW
Max. power: depends on the load impedance
Max. load current: 50 A
Coolant: water
Input connector: 7/16 jack, 7/8'' EIA (optional)
Output connector: 7/8'' EIA
Control system: local via CAN-Bus
Interfaces: RS 232 or Profibus
 

Dimensioned drawing: 

( Ansicht von oben )
( Seitenansicht )

PRODIK-T 75

Automatically tuned impedance matching network for medium load currents 

Operating frequency: 13.56 MHz
Nominal power: 7 kW
Max. power: depends on the load impedance
Max. load current: 75 A
Coolant: water
Input connector: 7/8'' EIA, jack (optional)
Output connector: customized
Control system: local via CAN-Bus
Interfaces: RS 232 or Profibus

PRODIK-T 130

Automatically tuned impedance matching network for high load currents

Operating frequency: 13.56 MHz
Nominal power: 10 kW
Max. power: depends on the load impedance
Max. load current: 130 A
Coolant: water
Input connector: 7/8'' EIA, jack (optional)
Output connector: customized
Control system: local via CAN-Bus
Interfaces: RS 232 or Profibus
 

Dimensioned drawing: 


( Seitenansicht )
( Vorderansicht )

PRODIK-T 160

Automatically tuned impedance matching network for high load currents

Operating frequency: 13.56 MHz
Nominal power: 15 kW
Max. power: depends on the load impedance
Max. load current: 160 A
Coolant: water
Input connector: 7/8'' EIA, jack (optional)
Output connector: special coaxial connector, adaptable, water-cooled (optional)
Control system: local via CAN-Bus
Interfaces: RS 232 or Profibus
 

Dimensioned drawing: 

PRODIK-T 300

Automatically tuned impedance matching network for very high load currents

 

Operating frequency: 13.56 MHz
Nominal power: 30 kW
Max. power: depends on the load impedance
Max. load current: 300 A
Coolant: water
Input connector: 1 5/8''
Output connector: customized
Control system: local via CAN-Bus
Interfaces: RS 232 or Profibus
 

Dimensioned drawing:

PRODIK-N 35

Automatically tuned impedance matching network (N-network)

Operating frequency: 13.56 MHz
Nominal power: 3 kW
Max. power: depends on the load impedance
Max. load current: 35 A
Coolant: water
Input connector: 7/16 jack
Output connector: 7/8'' EIA
Control system: local via CAN-Bus
Interfaces: RS 232 or Profibus
 

Dimensioned drawing: 

( side view  )